Skip to main content
Staging

BlazeFrame® (IAN)

BLAZEFRAME (IAN)

Angle profile with firestop applied to long leg, for use in fire rated wall assemblies.

Angle profile with firestop applied to long leg, for use in fire rated wall assemblies.

When used in conjunction with mineral wool, IAN is UL 2079-fifth edition compliant.  Provides joint protection for up to 3" with UL 2079 Class II or III Movement Capabilities. A 2mm thickness of cured intumescent material adhered to metal profiles provides air and smoke seals. When exposed to heat above 375 degrees Fahrenheit, the intumescent material expands up to 35 times its size. This provides protection from heat and flame passage during a fire event..

  • UL Classified and Listed Joint Systems
  • Intumescent strip provides air & smoke seals
  • Patents: www.cd-patents.com

Code Approvals & Performance Standards

  • AISI S100-16 (2020) w/S2-20 North American Specification for the Design of Cold-Formed Steel Structural Members
  • AISI S220-20 North American Standard for Cold-Formed Steel Framing - Nonstructural Members
    • (Compliant to ASTM C645, but IBC replaced with AISI S220 in IBC 2015)
    • Section A3 Material - Chemical & mechanical requirements (Referencing ASTM A1003/A1003M)
    • Section A4 Corrosion Protection (Referencing ASTM A653/A653M)
  • AISI S240-20 North American Standard for Cold-Formed Steel Structural Framing
    • (Compliant to ASTM C955, but IBC replaced with AISI S200 in IBC 2015, AISI S240 in IBC 2018)
    • Section A3 Material - Chemical & mechanical requirements (Referencing ASTM A1003/A1003M)
    • Section A4 Corrosion Protection (Referencing ASTM A653/A653M)
  • UL Designs 2079 Fifth Edition Tests for Fire Resistance of Building Joint Systems
    • (When used in conjunction with mineral wool insulation)
    • IBC requires fire-resistant joint systems be tested in accordance w/the requirements of either ASTM E1966 or UL 2079.
  • UL File number XHHW.R26034 BlazeFrame fire rated assemblies
  • SDS BlazeFrame Tape - Combined Intumescent Fire-Stop System
  • SDS For ASTM A1003 Steel Framing Products For Interior Framing, Exterior Framing and Clips/Accessories

CAD Details

Note: to view all of ClarkDietrich's CAD details, visit the CAD Details Library.

CDBS_IAN-UD-2
IAN Perpendicular to Unprotected Deck - 1
CDBS_IAN-UD-2

PRoduct submittal SHeets

Click the below Product Code to view Submittal/Tech Datasheet.

Product CodeDescription
IANBlazeFrame® (IAN) Systems

ClarkDietrich SubmittalPro®

Submittal sheets for the exact product you're looking for can be created by using ClarkDietrich's SubmittalPro® Product Submittal System.